3 2 Repair Manual RRE140/160/180/200/250 © BT
General safety rules
Electrical system
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
3.2 Electrical system
When working on the electrical system of the truck, remember the fol-
lowing:
a short circuit may occur if metal objects come into contact with live
connections. This can result in burns. So remove watches, rings and
other metal jewellery before starting work.
always use insulated tools while working on the electrical system.
always switch off the truck's power supply before opening the hoods
to the drive assembly and the electrical system.
disconnect the battery when using electric welding equipment. The
welding current may damage the battery.
always remove the battery plug when carrying out maintenance on
the truck, unless the instructions in this service manual state other
-
wise.
blow electric motors clean using compressed air.
clean electrical panels, electronic cards, connectors, contactors, so-
lenoid valves, etc. with a moist cloth and a cleaning agent that will
not damage the part.
IMPORTANT
Risk of short-circuiting that may damage electrical components.
Do not break the warranty seal on the electronic cards.