LinkStation User Manual 202
Appendix
The Info/Error LED blinks red to indicate an error. The error may be identied by the pattern of
blinking.
Note:
The error may also be viewed from NAS Navigator2.
Error code Descriptions
E04 The rmware is corrupted. Contact Bualo technical support for assistance.
E10 The LinkStation is running on the UPS battery due to a power outage. The system
will now be shut down safely. Check that power is being supplied to the UPS, and if
there are no problems, turn on the LinkStation.
E11 An error occurred in the fan speed. Check that no foreign objects or dust are
clogging the fan. If any foreign objects or dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the error is displayed again, contact Bualo
technical support for assistance.
E12 System temperature has exceeded the maximum safe value. Do not place objects in
the area around the LinkStation. Also, move the LinkStation to a cooler location.
E13 An error occurred in the RAID array. It will run in degraded mode until the error is
corrected. Contact Bualo technical support for assistance
Place Status
10s place The LED illuminates for 1.0 second every 0.3 seconds.
The number of ashes is the tens place of the error code.
1s place The LED illuminates for 0.5 seconds every 0.3 seconds.
The number of ashes is the ones place of the error code.
I28 Formatting a USB hard drive.
I46 Data migration or conversion (RAID migration) is in progress. Do not turn
o the LinkStation power.
I47 Data migration or conversion (RAID migration) is in progress. Do not turn
o the LinkStation power.
Info/Error LED glowing amber
When new rmware is available, the Info/Error LED will glow amber. Update the rmware as
described on page 112.