SYSTEM DESCRIPTION
Binary outputs
electrically isolated
current limitation 100 mA, output is clocked
Binary input
electrically isolated
0 ... 5 V = log "0", 10 ... 30 V = log "1"
inverted output reversed accordingly
PNEUMATIC DATA
Control medium Qualitiy Classes to DIN ISO 8573-1
Dust content Class 5
max. particle size 40 µm, max. particle density 10 mg/m
3
Water content Class 3
max.pressure dew point
- 20 °C or min. 10 deg. below the lowest operating temperature
Oil content Class 5
max. 25 mg/m³
Temperature range of
compressed air -10 ... + 50 °C
Pressure range 3 ... 7 bar
Supply pressure variation max. ± 10 % during operation
Air flow capacity of
control valve 100 l
N
/ min STP (for pressurizing and exhausting)
(Q
Nn
- value acc. to definition on pressure drop from 7 to 6 bar abs.)
Intrinsic air consumption
with zero control output 0.0 l
N
/min STP
Connections G 1/4’ internal thread G / NPT / RC