Chapter 2: System Hardware
Table 54 Force 300-19R Series – rear interfaces
Power over Ethernet (PoE).
Force 300-19R specifications
The Force 300-19R integrated module conforms to the specifications listed in Table 55 and Table 56.
The integrated module meets the low-level static discharge specifications identified in Electromagnetic
compatibility (EMC) compliance and provides internal surge suppression but does not provide lightning
suppression.
Table 55 Force 300-19R physical specifications
27.8 cm x 27.8 cm x 4.5cm (10.9 in x 10.9 in x 1.8 in)
1.45 kg (3.2 lbs) (Including mounting bracket)
Table 56 Force 300-19R environmental specifications
-30°C (-22°F) to +60°C (140°F)
113 mph (180 kph) maximum. See Force 300-19R wind loading for a full description.
IP67
Note
This product meets the UL/cUL 62368 / IEC 62368 edition 2
specification, and the radio housings are designed to be rain-tight.
Force 300-19R heater
At startup, if the Force 300-19R module temperature is at or below 32°F (0°C), an internal heater is
activated to ensure that the device can successfully begin operation. The unit’s heater is only activated
when the unit is powered on and will not apply heat to the device once the startup is complete. When the
unit temperature is greater than 32°F (0°C), the heater is deactivated, and the unit continues its startup
sequence.
The effect on device startup time at various temperatures is defined in Table 57.