6-MAINTENANCE
9.Openthefuelpre-ltervalve(A).
10.Performairbleedingforthefuelline.
SMIL13CEX2764AB3
NOTICE:whenthefuelpre-lterorthefuelmainlterhasbeenreplacedand/orthefueltankhasbeendrainedandis
emptyoffuel,airinthetankcouldinterferewiththeowofthefuel.Therefore,alwaysbleedtheairfromthefuelline.
Tobleedtheairfromthefuelline,proceedasfollows:
1.Openthefuelpre-ltervalve(A).
2.Switchthefuelmainltervalve(B)tothetank
side.
3.Loosentheairbleedscrew(1)ofthefuelmain
lter.
NOTE:donotloosentheairbleedscrewofthefuelprelter.
SMIL13CEX2765AB4
SMIL13CEX2766AB5
4.Insertthekeyintothestarterswitchandturnto
theONposition.Thismakestheelectromag-
neticfeedpump(4)operate.
NOTICE:iftheairbleedingisnotcomplete,donotleave
thestarterswitchONforlongerthan5min.Thiscould
causedamagetotheelectromagneticfeedpump.
SMIL13CEX2767AB6
6-34