EasyManua.ls Logo

Cessna 150M - Trouble Shooting-Pitot Tube Heater; Pitot Tube Alignment; Vacuum System

Cessna 150M
358 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15-21.
TROUBLE SHOOTING--VERTICAL
SPEED
INDICATOR. (Cont)
TROUBLE PROBABLE CAUSE REMEDY
POINTER
OSCILLATES.
(cont).
Leak
in
static
line.
Test
lines
and
connections
for
leaks.
Repair
or
replace
dam-
aged
lines,
tighten
connections.
Leak
in
instrument
case.
Substitute
known-good
indicator
and
check
reading.
Replace
instrument.
HAND VIBRATES.
Excessive
vibration.
Check
shock
mounts.
Replace
defective
shock
mounts.
Defective
diaphragm.
Substitute
known-good
indicator
and
check
for
vibration.
Re-
place
instrument.
15-22.
TROUBLE
SHOOTING--PITOT
TUBE
HEATER.
TROUBLE PROBABLE CAUSE REMEDY
TUBE DOES NOT HEAT
OR
Switch
turned
"OFF."
Turn
switch
"ON. "
CLEAR
ICE.
Blown
fuse.
Check
fuse.
Replace
fuse.
Break
in
wiring.
Test
for
open
circuit.
Repair
wiring.
Heating
element
burned
out.
Check
resistance
of
heating
15-23.
PITOT
TUBE ALIGNMENT.
(Refer
to
fig-
ure
15-2.)
For
correct
airspeed
indication
pitot
tube
(18)
must
be
properly
aligned.
Open end of
tube
must
be
perpendicular
to
longitudinal
axis
of
aircraft.
A
template
like
the
one
shown
in
figure
15-4
will
prove
the
most
convenient
means
of
checking
align-
ment.
Prior
to
using
template,
check
that
pitot
tube
parallels
row
of
rivets
just
outboard
of
tube.
A
straightedge
may
be
placed
along
row
of
rivets
to
check
the
alignment.
The
template
fits
over
the
wing
leading
edge
and
should
conform
to
the
illustration.
the
illustration
has
been
drawn
carefully
to
actual
size
and
may
be
traced
directly
on
a
piece
of
carbon
paper
between
the
printed
page
and
the
template
ma-
terial,
then
trace
contours.
15-24.
VACUUM SYSTEM.
(Refer
to
figure
15-5.)
element.
Replace
element.
15-25.
DESCRIPTION. Suction to
operate
the
gyros
is
provided
by
a
dry-type
engine-driven
vacuum
pump,
gear-driven
through
a
spline-type
coupling.
A
suction
relief
valve,
to
control
system
pressure,
is
connected
between
the
pump
inlet
and
the
instru-
ments.
In
the
cabin,
the
vacuum
line
is
routed
from
gyro
instruments
to
the
relief
valve
at
the
firewall.
A
central
air
filtering
system
is
utilized.
Beginning I
with
aircraft
serial
15075525 and A1500480 a
throw
away
type
air
filtering
unit
is
installed.
The
unit
is
installed
with
sta-straps
for
quick
change
capability.
The
reading
of
the
suction
gage
indicates
net
differ-
ence
in
suction
before
and
after
air
passes
through
a
gyro.
This
differential
pressure
will
gradually
de-
crease
as
the
central
aii'
filter
becomes
dirty,
caus-
ing
a
lower
reading
on
the
suction
gage.
Change
2
15-9

Table of Contents

Related product manuals