TROUBLE SHOOTING--GYROS. (Cont).
TROUBLE
PROBABLE
CAUSE REMEDY
HORIZON BAR OSCILLATES
Central
filter
dirty.
Check
filter.
Clean
or
replace
OR
VIBRATES EXCESSIVELY.
filter.
Suction
relief
valve
im-
Adjust
or
replace
relief
valve.
properly
adjusted.
Faulty
suction
gage.
Substitute
known-good
suction
gage
and
check
gyro
indication.
Replace
suction
gage.
Defective
mechanism.
Substitute
known-good
gyro
and
check
indication.
Replace
in-
strument.
Excessive
vibration.
Check
panel
shock-mounts.
Re-
place
defective
shock-mounts.
EXCESSIVE
DRIFT
IN
Central
air
filter
dirty.
Check
filter.
Clean
or
replace
EITHER
DIRECTION.
filter.
Low
vacuum,
relief
valve
Adjust
or
replace
relief
valve.
improperly
adjusted.
Faulty
suction
gage.
Substitute
known-good
suction
gage
and
check
gyro
indication.
Replace
suction
gage.
Vacuum
pump
failure.
Check
pump.
Replace
pump.
Vacuum
line
kinked
or
Check
lines
for
damage
and
leaking.
leaks.
Repair
or
replace
dam-
aged
lines,
tighten
connections.
DIAL SPINS IN ONE
Operating
limits
have
been
Replace
instrument.
DIRECTION CONTINU-
exceeded.
OUSLY.
Defective
mechanism.
Substitute
known-good
gyro
and
check
indication.
Replace
instrument.
SHOP
NOTES:
15-12