Remote Operation
5-77
PROGram:SEQuence:REMain
Type: Channel-Specific
Description: This command returns the remains sequence of unused.
Setting Syntax: None
Setting Parameters:None
Query Syntax: PROGram:SEQuency:REMain?
Return Parameters:<NR1>
Query Example: PROG:SEQ:REM?
PROGram:SEQuence:SPECification?
Type: Channel-Specific
Description: This query returns the specification of program sequence from the
DC Electronic Load in binary format. The specification either voltage
current or power are consist of total sequences in program file that
user specified in format of 32bits float point.
Setting Syntax: None
Setting Parameters:None
Query Syntax: PROGram:SEQuency:SPECification?<space><Arg1>,<Arg2>
Selects a program:
Arg1: <NR1>, 1 ~ 10, Resolution = 1, Unit = None.
Selects a parameter of measurement:
Arg2: <NRf>, V(0), I(1), P(2), Unit = None.
Return Parameters: <DLABRD>, for example: when the 12 sequences in program 1,
than the return will be the format show in below.
Query Example: PROG:SEQ:SPEC? 1,V
Return Example: None
#3048<byte1><byte2><byte3><byte4><byte5><byte6><byte7><byte8>
、、、
Sequence #1
Sequence #2
Low byte
―――→
High byte