Chapter 2 Operating Principles
2-3. Operation Panel
CL-S400DT 2-40
Submenu Name
[Factory Mode Settings
Menu name]
Adjustable Value
(Default Value)
Description
Auto Cal Mode
[AutoCal Mode]
On/Off
(On)
Automatically controls the light amount of each
media sensor.
Through LED
[See Through Sensor]
0.0 to 3.3V
(0.0 V)
This menu is effective when “Auto Cal Mode” is
set to OFF. The light amount emitted from the
light emitter of the adjustable sensor can be
changed when “Media Sensor” submenu is set
to “See Through”.
Reflect LED
[Reflect Sensor]
0.0 to 3.3V
(0.0 V)
This menu is effective when “Auto Cal Mode” is
set to OFF. The light amount emitted from the
light emitter of the adjustable sensor can be
changed when “Media Sensor” submenu is set
to “Reflect”.
Thru Sensitiv
[See Through Sensitivity]
Low, Medium,
High (Low)
This menu is effective when “Auto Cal Mode”
submenu is set to OFF. The sensitivity of
transparent sensor (adjustable sensor) can be
changed in three steps.
Refl Sensitiv
[Reflect Sensitivity]
Low, Medium,
High (Low)
This menu is effective when “Auto Cal Mode”
submenu is set to OFF. The sensitivity of
reflective sensor (adjustable sensor) can be
changed in three steps.
Cal Thru Level
[Through Cal Level]
0.01 to 3.30V
(2.30V)
Performs sensitivity adjustment of the adjustable
sensor for “Media Sensor” submenu “See
Through”. The amount of light received is set to
“2.30V”.
Cal Refl Level
[Reflect Cal Level]
0.01 to 3.30V
(2.10 V)
Performs sensitivity adjustment of the adjustable
sensor for “Media Sensor” submenu “Reflect”.
The amount of light received is set to “2.10V”.
Cal None Level
[SensNone Cal Level]
0.01 to 3.30V
(2.05 V)
Performs sensitivity adjustment of the adjustable
sensor for “Media Sensor” submenu “None”.
The amount of light received is set to “2.05V”.
Peel Sens Level
0.01 to 3.30V
(1.50 V)
Sets the threshold value for the peel sensor.
Cont Paper Sens
Through/Reflect
(Reflect)
When continuous media is used, selects the
sensor type to be used for detecting paper end.
Darkness Rate
[Darkness Rate]
High, Low
(High)
Selects the rate to increase or decrease the
print darkness.
Dbl Heat Menu
[Double Heat Menu]
On/Off
(Off)
Selects whether to display the menu of "Double
Heat" or not.
PwrOn Head Chk
[PowerOn Head Check]
On/Off
(On)
Selects whether to perform head check at power
ON or not.
Head Chk Start
[Head Check Start Pos.]
Dots 001 to 848
(Dot 001)
Designates the start dot for head check.
Head Chk Stop
[Head Check Stop Pos.]
Dots 001 to 848
(Dot 848)
Designates the end dot for head check.
Parallel ErrOut
[Parallel Error Output]
On/Off
(On)
Select whether to activate the Fault signal of
parallel interface at the time of error occurrence
or not.