Chapter 3 Disassembly and Maintenance
3-7 Adjustment
CL-S400DT 3-30
2. In “Factory Setup” main menu, press the [STOP] (X) key to enter Factory Setup
mode.
The first submenu “Init Thru Sen” is displayed.
3. Press the [MENU] (T) key until “Init Refl Sen” submenu appears.
4. Press the [STOP] (X) key to enter “IInit Refl Sen” sensitivity adjustment mode.
5. Press the [MENU] (T) key to select “Exec”.
6. Press the [STOP] (X) key to execute adjustment.
Adjustment starts and the following screen is display.
7. Be sure that adjustment is successfully completed and the following screen is
displayed. (The value “123” is an example.)
When adjustment failed:
“Cannot Setup” is displayed. In this case, follow the next
steps.
1) Press any key of the printer.
The screen returns to that in Step 3.
2) Check for correct media setting position, media, active
sensor, etc. and repeat from Step 3.
8. Press any key of the printer.
Then, the obtained value is saved into the printer and the screen returns to Step 3.
9. Press the [PAUSE] (W) key to return to “Factory Setup” menu.
10. Press the [PAUSE] (W) key once again.
The changed value is saved in the printer and the printer is turned OFF and then
ON for normal operation.
Init Refl Sen
No
S
T
Init Adj-Refl
Exec
S
T
Factory Setup
Init Refl Sen
S
T
Now !!
Executing
S
T
Finished
DAC 123
S
T
Cannot
Setup
S
T