- 116 -
fn = 5: Function 5 Setting Customized Value
GS ( E pL pH fn [a1 n1L n1H]...[ak nkL nkH]
[Code] <1d>H<28>H<45>H pL pH fn [a1 n1L n1H]...[ak nkL nkH]
[Range] 4(pL + pH x256) 65535
fn = 5
1a3 a = 5, 6, 97, 116, 201, 202
1(nL + nH x256) 65535
[Default] Described in the processing table for “a”.
[Outline] • Sets the customized value set in “a” to (nL + nH x256).
a Function
1
Specifies user NV memory capacity.
2
Specifies the memory capacity of NV graphics.
3 Selects paper width.
5 Selects printing density.
6 Selects printing speed.
116 Selects printing color.
201 Sets ACK output position (only parallel I/F).
202 Selects input buffer full Busy output/cancel timing (idle capacity).
• a = 1: Sets the user NV memory capacity to the size specified by (nL + nH × 256).
(nL + nH × 256) Memory Capacity
1 (Default) 1K bytes
2 64K bytes
3 128K bytes
4 192K bytes
• a = 2: Sets NV graphic memory capacity to the size specified by (nL + nH x 256).
(nL + nH × 256) Memory Capacity
1 None
2 64K bytes
3 128K bytes
4 192K bytes
5 256K bytes
6 320K bytes
7 (Default) 384K bytes