- 128 -
fn = 12: Function 12 Sending the Set Communication Conditions
GS ( E pL pH fn a
[Code] <1d>H<28>H<45>H pL pH fn a
[Range] (pL + pH x256) = 2 (pL = 2, pH = 0)
fn = 12
1a4,119,120 (Does not send in other than specified range)
[Outline] Sends communication conditions of serial interface specified by “a”.
Hex. No. of Data
Header 37H 1
ID 33H 1
Kind of communication conditions (a) 31H (“1”) ~ 34H (“4”) 1
Separation number 1FH 1
Set value 30H ~ 39H 1 ~ 6
NULL 00H 1
Set value
• a = 1: At specification of baud rate
Baud
Rate
d1 d2 d3 d4 d5 d6
2400 50 (“2”) 52 (“4”) 48 (“0”) 48 (“0”)
4800 52 (“4”) 56 (“8”) 48 (“0”) 48 (“0”)
9600 57 (“9”) 54 (“6”) 48 (“0”) 48 (“0”)
19200 49 (“1”) 57 (“9”) 50 (“2”) 48 (“0”) 48 (“0”)
38400 51 (“3”) 56 (“8”) 52 (“4”) 48 (“0”) 48 (“0”)
57600
53(“5”) 55(“7”) 54(“6”) 48(“0”) 48(“0”)
115200
49(“1”) 49(“1”) 53(“5”) 50(“2”) 48(“0”) 48(“0”)
• a = 2: At specification of parity
d1 Parity Setting
48 No parity
49 Odd parity
50 Even parity
• a = 3: At specification of flow control
d1 Flow Control
48 DSR/DTR
49 XON/XOFF
• a = 4: At specification of data length
d1 Setting Data Length
48 7-bit length
49 8-bit length