EasyManua.ls Logo

Citizen CT-S2000 - GS ^ N1 N2 N3 (Executing the Macro)

Citizen CT-S2000
191 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 68 -
GS ^ n1 n2 n3
[Function] Executing the macro
[Code] <1D>H<5E>H<n1><n2><n3>
[Range] 0n1255
0n2255
0n31
[Outline] Executing contents defined in macro.
n1 : The number of times of macro execution
n2 : Waiting time on macro execution: Waiting time of n2 x 100 msec is given for every
execution.
n3 : Macro execution mode
n3 = 0 Continuous execution: The Macro is executed “n1” times continuously at the
time interval specified by “n2”.
n3 = 1 Execution by FEED Switch: After waiting for the time specified by “n2”, the
ARARM
LED flickers and the FEED switch is waiting to be
pressed. When it is pressed, the macro is executed
once. This action is repeated “n1” times.
[Caution] • When this command is received while in macro definition, suspension of macro
definition is indicated. At this time, the defined content is cleared.
• No execution takes place when the macro is held undefined.
• While in macro execution with n3 = 1, paper feed with the FEED switch is not
available.
[See Also] GS :
[Sample Program]
Refer to Sample Program and Print Results for GS:.