EasyManua.ls Logo

Citizen CT-S2000 - Page 123

Citizen CT-S2000
191 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 121 -
• a = 6: When printing speed is specified
Setting Status Sending Data
Stored
Value
Print
Density
1st
Byte
2nd
Byte
3rd
Byte
4th
Byte
5th
Byte
1 Speed level 1 49 (“1”)
2 Speed level 2 50 (“2”)
3 Speed level 3 51 (“3”)
4 Speed level 4 52 (“4”)
5 Speed level 5 53 (“5”)
6 Speed level 6 54 (“6”)
7 Speed level 7 55 (“7”)
8 Speed level 8 56 (“8”)
9 Speed level 9 57 (“9”)
• a = 116: When kind of paper is specified
Setting Status Sending Data
Store
d
Value
Print Control
1st
Byte
2nd
Byte
3rd
Byte
4th
Byte
5th
Byte
1 Single-color paper 49 (“1”)
2 2-color paper 50 (“2”)
• a = 201: When ACK output position is specified
Setting Status Sending Data
Stored
Value
ACK Output
Position
1st
Byte
2
nd
Byte
3rd
Byte
4th
Byte
5th
Byte
1 ACK-in-Busy 49 (“1”)
2 ACK-while-Busy 50 (“2”)
3 ACK-after- Busy 51 (“3”)
• a = 202: Input buffer full Busy output/cancel timing
In case of MSW1-2 ON (Buffer size is 45 bytes)
Setting Status Sending Data
Stored
Value
BUSY
Output/Cancel
1st
Byte
2nd
Byte
3rd
Byte
4th
Byte
5th
Byte
1 16/26 49 (“1”)
2 16/36 50 (“2”)
3 8/26 51 (“3”)
4 8/36 52 (“4”)
In case of MSW1-2 OFF (Buffer size is 4K bytes)
Setting Status Sending Data
Stored
Value
BUSY
Output/Cancel
1st
Byte
2nd
Byte
3rd
Byte
4th
Byte
5th
Byte
1 128/256 49 (“1”)
2 128/512 50 (“2”)
3 72/256 51 (“3”)
4 72/512 52 (“4”)

Table of Contents