- 177 -
Switch No. Setting Default Set Values
MSW7-1 Baud Rate 19200 bps 1200 bps, 2400 bps, 4800 bps, 9600 bps,
19200 bps, 38400 bps, 57600 bps, 115200 bps
MSW7-2 Data Length 8 bits 7 bits, 8 bits
MSW7-3 Stop Bit 1 Bit 1 Bit, 2 Bits
MSW7-4 Parity NONE NONE, ODD, EVEN
MSW7-5 Flow Control DTR/DSR DTR/DSR, XON/XOFF
MSW7-6 DMA control Valid Valid, Invalid
MSW7-7 VCom Protocol PC setting PC setting, DTR/DSR, XON/XOFF
MSW8-1 Print Width 576 dots 640 dots, 576 dots, 512 dots, 436 dots, 432 dots,
420 dots, 384 dots, 360 dots
MSW8-2 Paper Type 1 Color
Normal
1 Color Normal, 1 Color B.M, 1 Color Label,
2 Color Normal, 2 Color B.M
MSW9-1 Code Page PC437 PC437, Katakana, PC850,858, PC860, PC863,
PC865, PC852, PC866, PC857, WPC1252, PC864,
ThaiCode18
MSW9-2 Int’Char Set USA USA, France, Germany, England, Denmark,
Sweden, Italy, Spain, Japan, Norway, Denmark 2,
Spain 2, Latin America, Korea
MSW9-3 Kanji OFF ON, OFF
MSW9-4 JIS/Shift JIS JIS JIS, Shift JIS
MSW10-1 Print Density 100% 70%, 75%, 80%, 85%, 90%, 95%, 100%,
105%, 110%, 115%, 120%, 125%, 130%,
135%, 140%
MSW10-2 Print Speed Level 9 Level 1 , Level 2, Level 3, Level 4, Level 5, Level 6,
Level 7, Level 8, Level 9
MSW10-3 ACK Timing Before BUSY Before Busy, Same Period, After Busy