TIC QUANTUM Hydraulics
10/04 11-101
4.8.3 No working function
with multiple
actuation
Fault Cause Remedy
Function only at consumer with
lowest pressure demand
Pump oil delivery too low
Non-return valve in load
signalling line leaking as it
does not close its ball or its
ball is missing
Replace or clean pump
Install ball if missing
Insufficient function at one
consumer
Ram of directional control
valve works stiffly
Remove and clean
4.8.4 Consumers lower
Fault Cause Remedy
Internal leak at the directional
control valve too high
Control spool or valve body
worn
Replace directional
control valve
4.8.5 Oil heating-up
Fault Cause Remedy
System pressure build-up in neutral
position
Incorrect valve mounting
plate, no control oil return
Z - T
Replace plate
Circulation pressure too high
Directional control valve
does not return fully to the
neutral position as
connecting screws are
tightened too much (30 Nm)
Reduce tightening torque
4.8.6 External oil leaks
Fault Cause Remedy
Oil leak between plates
Sealing plate damaged Replace
Foreign object between O-
ring and seal surface
Clean
Seal surface damaged,
possibly due to a blow on
the edge
Dress surface
Oil leak at solenoid
Sealing damaged Replace
Oil leak at pressure pilot valve unit
Sealing nut not locked or
cutting edge of drain plug
damaged
Tighten or replace
Sealing nut damaged Replace
Oil leak at screw plug
Screw plug loose
Copper seal damaged
Tighten
Replace