TIC QUANTUM Electric System
10/04 12-23
2.4 Setting of reed switches
To ensure flawless function of the reed switches, the position of each
switch relating to the associated magnet must be correct.
Adjust setting as follows:
Move the reed switch and/or the magnet to the position where the
switching operation is to take place.
Set the distance between the reed switch and the magnet to 1-3 mm
The magnet must be set to an offset of approx. 10-15 mm to the
centre of the reed switch since the centre of a reed switch is in a
dead field.