Group 19, Motor Controls
19-3-16 • CONTROL TROUBLESHOOTING SM 765, Dec ’06
Fault
Code
Fault Name Fault Description Control Troubleshooting
Action
Required
232 "MASTER
KO"
Slave micro pro-
cessor detects
Master processor
malfunctioning
SLAVE Slave and Master microprocessor per-
form a crosscheck in order to verify
functionality. There are two conditions
under which the slave enters this fault
condition:
The SLAVE microprocessor receives an
incoherent Can message from the MAS-
TER microprocessor.
The SLAVE microprocessor compares
the inputs status and the related MAS-
TER operations and finds they are not
coherent. In both cases, the SLAVE
brings the controller to a safe status
opening the power bridge and the line
contactor.
233 "NO CAN
MSG 3"
Slave has lost Can
communication
with Pump
SLAVE Slave (node #4) signals that it has lost
communication with the Master (node
#3) This fault could be determined to be
a problem in the truck CAN-BUS line or
be an internal problem in the controller
logic card. First check the CAN_BUS
connection.
235 "THERMIC
SENSOR
KO"
Warning: Slave
temperature sen-
sor is our of
range
SLAVE The range of the temperature sensor is
always checked and a warning is sig-
naled if it is out of range. This fault will
reduce the maximum current output of
the controller to 50%.
236 "INPUT
MIS-
MATCH"
Slave micro pro-
cessor has
detected a mis-
match between
inputs status and
the input status
transmitted Via
Canbus by master
micro processor
SLAVE Safety related inputs (Fwd direction, Rev
direction, accelerator Enable, Seat
switch) are inputs to both micro proces-
sors by independent hardware circuit.
The two microprocessors read these
inputs and compare by exchanging
related status on the Canbus. If the
SLAVE microprocessor finds a mismatch
between its inputs and MASTER inputs,
it brings the controller to a safe status
opening the power bridge and the line
contactor.
243 "NO CAN
MSG 5"
Master has lost
Can communica-
tion with Pump
MASTER Master (node #3) signals that it has lost
communication with the Pump (node #5)
This fault could be determined to be a
problem in the truck CAN-BUS line or
be an internal problem in the controller
logic card. First check the CAN_BUS
connections.