EasyManuals Logo

COBHAM SAILOR 60 GX-R2 4.5 W User Manual

COBHAM SAILOR 60 GX-R2 4.5 W
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Site preparation
3-16 Chapter 3: Installation 98-148248-C
3.2.8 Condensation, water intrusion and deposits
In some weather conditions there may occur condensation inside the radome. The drain
tube is designed to lead any water away from inside the radome.
Observe the following guidelines for condensation and water intrusion:
1. If possible, install the radome such that direct spray of seawater is avoided.
2. Make sure the ADU’s drain tube is open and that there it free space between the drain
tube and the mounting surface so water can escape and there is ventilation for the
ADU.
3. Do not use pneumatic tools for cleaning the radome, especially at a short distance and
directly at the split between top and bottom.
4. Do not place the ADU close to a funnel, as smoke deposits are corrosive. Furthermore,
deposits on the radome can degrade performance.
Figure 3-17: Drain pipe with free space

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the COBHAM SAILOR 60 GX-R2 4.5 W and is the answer not in the manual?

COBHAM SAILOR 60 GX-R2 4.5 W Specifications

General IconGeneral
BrandCOBHAM
ModelSAILOR 60 GX-R2 4.5 W
CategoryAntenna
LanguageEnglish

Related product manuals