Satellite profiles and modem profiles
6-30 Chapter 6: Configuration 98-148248-C
6.5.6 Setup of reports, syslog and SNMP traps
The antenna can send the following reports and messages:
Diagnostics report
Statistics report
Remote syslog
SNMP traps
Diagnostics report
The antenna can send automatically generated diagnostic reports at fixed intervals. The
diagnostic report contains information from the ADU and ACU that are relevant for the
service personnel during troubleshooting. The report contains data for the selected
download intervals.
To set up sending a statistics report, do as follows:
1. Select SETTINGS > Reporting.
2. In the section DIAGNOSTICS REPORT enter the following:
•E-mail sender.
E-mail recipients (comma separated).
Figure 6-24: Web interface: SETTINGS, Reporting