15
Setup Mode
Rejected Images
Automatically Save: If the sensor is Online and a failed
inspection is encountered, the filmstrip image is
automatically saved as a bitmap file to the specified
location.
Number to Save: Specifies the number of failed
inspection images to save. (VisionView Operator
Interface Panel: 10, 25, 50, 100, 250, 500, 800;
default = 10. VisionView PC software: 10, 25, 50, 100,
250, 500, 1000, All; default = 10.)
Operator Controls
Change Reject Action: Allows the operator to override the
reject action specified in Setup Mode. If the operator
changes the reject action while in Run Mode, the change is
only applied to the active sensor, and will persist if
VisionView is power-cycled or placed in Setup Mode.
Manually Save Images: Allows the operator to manually
save filmstrip images to the specified location.
Show AutoSave Failures: Allows the operator to enable
or disable warning messages that appear if the failed
inspection image is not automatically saved to the specified
location.
Location for Saving Images: Click Edit to specify the location for
saving filmstrip images as a bitmap file.
Note:
Use this method for saving failed images if you expect to
have approximately one inspection failure every ten seconds.
If you expect more failures than this, it is recommended that
you use a more robust solution, such as the In-Sight
WriteImageFTP function.
Note:
The file path can contain a maximum of 255 characters. The
file path refers to all of the characters from the root directory
through the file name and file extension.
Location for Saving Images: USB Drive
Figure 3-10: Location for Saving Images Screen
USB Location: Optionally, click Edit to specify a directory
on the USB drive for saving filmstrip images. The location
must be a valid directory path name (for example, “Images”
or “Images\Line1”). If the directory does not already exist, it
is automatically created. The images are stored in a
subdirectory that is automatically created, based on the
sensor’s Display Name.
Notes:
Do not connect more than one USB drive at a time to
VisionView.
When images are saved using the VisionView PC
software, they are saved to the first removable, writable
storage device detected on the PC.