GEN1000
OPERATOR MANUAL
287960-ENG
R00

Table of Contents

Questions and Answers:

Conviron GEN1000 Specifications

General IconGeneral
ModelGEN1000
Temperature Uniformity±0.5°C
ApplicationPlant growth
LightingFluorescent
CO2 ControlOptional
Power Supply230V/50Hz

Summary

PREFACE

Functional Description and Intended Use

Details the chamber's purpose for plant production and scientific experiments.

COMPLIANCE STATEMENTS

WEEE and RoHS Compliance

Statements regarding Waste Electrical and Electronic Equipment and Hazardous Substances directives.

Document Conventions

Explains symbols, text formatting, and figures used throughout the manual.

SERVICE AND TECHNICAL SUPPORT

PRECAUTIONS

Hazard Identification Symbols

Defines symbols used to warn of potential hazards and important information.

General Precautions

Provides essential safety guidelines for operating and maintaining the chamber.

CHAMBER FEATURES

Configurations Overview

Describes the different kit configurations available for the GEN1000 chamber.

Control System

Details the advanced programming and monitoring capabilities of the controller.

Air Intake and Exhaust Ports

Explains the function and adjustment of air exchange ports.

Instrumentation Ports

Describes the port for inserting instruments and monitoring leads.

Network Connectivity

Information on connecting the chamber to a facility network via an RJ45 port.

ADDITIONAL CHAMBER FEATURES

Levelers

Details the use of levelers for chamber stabilization.

Central Management System (Optional)

Overview of the optional system for remote control and monitoring.

CMP-Link (Optional)

Explains the CMP-LINK feature for enhanced chamber interaction.

Central Alarm Contact

Describes the connection for system alarms to external monitoring.

CHAMBER OPTIONS

Available Chamber Options

Lists various optional features like humidity, CO2, and lighting configurations.

INSTALLATION

Install the Chamber

Guidance on selecting a suitable location and environment for the chamber.

Chamber Clearance Requirements

Specifies the necessary space around the chamber for ventilation and access.

Power Supply Requirements

Details electrical specifications and voltage tolerance for the chamber.

INSTALLATION PROCEDURES

Water Supply Parameters

Lists the required water quality and connection specifications.

Condensate Drain Setup

Information on connecting or managing condensate drainage.

Remove Chamber from Shipping Pallet

Step-by-step instructions for safely removing the chamber from its pallet.

CHAMBER POSITIONING AND LEVELING

Move Chamber to Final Position

Guidance on safely moving the chamber to its intended location.

Level the Chamber

Instructions on adjusting levelers to ensure the chamber is stable and level.

CONFIGURATION KITS

Configuration Kit Overview

Introduction to the four specialized kits (SH, TA, TC, IN) for different applications.

Airflow Characteristics

Explanation of airflow distribution for different configuration types.

SHELF AND LIGHT CANOPY INSTALLATION

Adjustable Wire Shelves and Lamp Canopies

Details on installing shelves and lamp supports.

SPECIFIC CONFIGURATION INSTALLATION

Unifloor Installation (TA Kit)

Instructions for installing the Unifloor component in the TA Kit.

Install Light Canopies and Shelving Kits

General steps for installing configuration kits for various setups.

SH CONFIGURATION INSTALLATION

SH Configuration Details

Description of the Short Plant (SH) configuration and airflow.

To Install the SH Configuration Kit

Step-by-step guide for installing the SH configuration components.

TA CONFIGURATION INSTALLATION

TA Configuration Details

Description of the Tall Plant (TA) configuration and airflow.

To Install the TA Configuration Kit

Step-by-step guide for installing the TA configuration components.

TC CONFIGURATION INSTALLATION

TC Configuration Details

Description of the Tissue Culture (TC) configuration and airflow.

To Install the TC Configuration Kit

Step-by-step guide for installing the TC configuration components.

IN CONFIGURATION INSTALLATION

IN Configuration Details

Description of the Incubation (IN) configuration and airflow.

To Install the IN Configuration Kit

Step-by-step guide for installing the IN configuration components.

REMOVE CONFIGURATION COMPONENTS

Remove Light Canopies and Shelves

Procedure for removing existing shelves and light canopies.

Remove a Wire Shelf

Steps to remove a wire shelf from its clips.

Remove a Wire Shelf Clip

Instructions for detaching shelf clips from the pilaster.

Remove an Air Shelf

Procedure for removing an air shelf and its brackets.

ADDITIONAL COMPONENT REMOVAL AND CONNECTIONS

Remove Air Shelf Bracket

Steps to detach air shelf brackets.

Remove the Unifloor

Instructions for removing the Unifloor component.

Remove a Cover Plate

Procedure for detaching a cover plate.

Connect Back Panel Connections

Guide for connecting UPS, communication, and alarm contacts.

START UP PROCEDURES

Power ON

Pre-power on checks and sequence for turning on the chamber.

Start-Up Procedure

Step-by-step guide for initiating chamber operation.

POST START-UP CHECKS

Visual Checks

Confirms lights function and doors are light-tight.

OPERATION

Control and Monitoring

Overview of the CMP6060 controller interface and capabilities.

Fluorescent and LED Lighting

Information on standard and optional lighting systems.

LIGHTING OPTIONS AND DETAILS

Lighting Options Overview

Details programmable ranges and choices for lighting control.

Fluorescent Lighting

Description of the standard fluorescent lighting system.

LED Lighting Option

Benefits and characteristics of the LED lighting option.

Closed Loop Dimmable Lighting

Information on automatic light intensity adjustment.

OPERATIONAL COMPONENTS

Aspirator Function

Location and role of the aspirator in monitoring conditions.

Instrumentation Port Usage

Guidance on using the port for low-voltage wires.

AIRFLOW AND ENVIRONMENT CONTROL

Fresh Air Inlet and Exhaust Ports

Details on adjusting fresh air exchange rate and filter cleaning.

ENVIRONMENTAL CONTROL OPTIONS

Fan Speed Control

Information on adjusting fan speed for airflow control.

Plant Placement Guidelines

Advice on positioning plants within the chamber for optimal growth.

Bypass Dehumidification (BDH)

Explanation of the optional system for achieving lower humidity.

CARBON DIOXIDE (CO2) CONTROL

Additive CO2 Control Overview

Details the CO2 sensor and injection system for elevated levels.

Set up CO2 Control

Instructions for setting up the CO2 control system.

Adjust CO2 Control

Guidance on programming CO2 setpoints and air flow.

ADVANCED OPERATION FEATURES

Central Management System (CMS)

References manual for the optional Central Management System.

Shutdown Procedures

Instructions for proper shutdown when not in use for extended periods.

MAINTENANCE

General Safety Warnings

Crucial safety warnings regarding manual, electrical, and mechanical hazards.

Disconnect Power Before Maintenance

Essential steps to safely disconnect power before servicing.

Clean the Chamber

Procedure for routine cleaning of the chamber interior.

SPECIFIC MAINTENANCE TASKS

Replace Lamps

Guidance on inspecting and replacing fluorescent or LED lamps.

Burn Hazard Warning (Lamps)

Warning about potential burns from hot lamp tubes.

MACHINE COMPARTMENT MAINTENANCE

Perform Maintenance in Machine Compartment

Instructions for accessing and performing maintenance on the top compartment.

ULTRASONIC HUMIDITY SYSTEM (USH) MAINTENANCE

Maintain the Ultrasonic Humidity System

Procedures for cleaning and maintaining the USH box.

USH CERAMIC DISC REPLACEMENT

Replace Ceramic Discs

Instructions for replacing the ceramic discs in the USH system.

SENSOR CALIBRATION AND ADJUSTMENTS

Calibrate Temperature and Humidity Sensor

Guidance on yearly calibration of environmental sensors.

Adjust the Door

Instructions for adjusting the chamber door and warnings about pinch hazards.

Clean Condensate Pump and Pan

Procedure for cleaning the optional condensate pump and pan.

TROUBLESHOOTING

Troubleshooting Steps

General steps and common issues like chamber not starting or controlling.

DIAGNOSTIC INFORMATION

Fuse Schedule

List of fuses, their ratings, locations, and protected components.

TECHNICAL SPECIFICATIONS

ADDITIONAL INFORMATION

Terms and Definitions

Glossary of terms and abbreviations used in the manual.

Disposal Guidelines

Information on proper handling and disposal of the chamber components.