Chapter 7 Parameters
61
Name
Function
Rang
Default
Value
Position
command
smooth
filter
1.To filter the instruction pulse with exponential
acceleration and deceleration, and the value
represents the time constant.
2.The filter does not lose input pulses, but would
occur command delay .
3.The filter applies in
(1. PC controller without acceleration and
deceleration function.
(2. The electronic gear frequency is a little big(>10).
(3.The command frequency is a little low.
(4.When the motor runs, there are step jumps and
unsmooth.
4.When set to value”0”, the filter does not work.
0-1000×0.
1ms
100
Invalid
input of
drive
inhibition
To set:
0: CCW drive inhibition or CW drive inhibition is
effective. If the switch of CCW drive inhibition is
ON, CCW drive is permitted.If the switch of CCW
drive inhibition is OFF, CCW torque keeps 0.The
same as CW drive inhibition. If both CCW and CW
drive inhibition are OFF, it will come to error alarms
of drive inhibition input.
1: Cancel CCW or CW drive inhibition. No matter
what state of the switch of CCW or CW drive
inhibition is, CCW or CW drive is
allowed.Meanwhile,if the switches of CCW and
CW drive inhibition are OFF, it will still not alarm..
0-1
1
JOG speed
Set the running speed of JOG operating.
0-6000
r/min
100