Chapter 7 Parameters
63
Name
Function
Rang
Default
Value
Internal
speed
selection 1
1.Set the internal speed 1.
2.In speed control mode(FA22=0), when SF1 and
SF2 are OFF, internal speed 1 is the speed command.
-6000-
6000
r/min
100
Internal
speed
selection 2
1.Set the internal speed 2.
2.In speed control mode(FA22=0), when SF1 is
ON,while SF2 is OFF, internal speed 2 is the speed
command.
-6000-
6000
r/min
500
Internal
speed
selection 3
1.Set the internal speed 3.
2.In speed control mode(FA22=0), when SF1 is
OFF,while SF2 is ON, internal speed 3 is the speed
command.
-6000-
6000
r/min
1000
Internal
speed
selection 4
1.Set the internal speed 4.
2.In speed control mode(FA22=0), when SC1 and
SC2 are ON, internal speed 4 is the speed command.
-6000-
6000
r/min
2000
Speed
arrival
1. When the motor speed exceeds this parameter, the ASP
of the digital output DO
(speed reached) ON, otherwise OFF.
2. The comparator has hysteresis function, which is set by
parameter FA87.
3. .It also has the polarity setting function:
FA88
FA28
Comparator
0
>0
No direction for speed
1
>0
Only detect CCW speed
<0
Only detect CW speed
0-3000
r/min
3000
Gain of
analog
quantity
torque
command
1.Set the proportion for input voltage of analog
torque and the actual motor running torque.
2. The setting value unit is 0.1v/100%.
3. The default value is 30, corresponding to
3v/100%, while it means if the input voltage is 3V, it
would generate 100% rated torque.
10-100
(0.1v/
100%)
30