Chapter 7 Parameters
71
73
MODBUS
protocol
selection
0: 8, N, 2 (MODBUS, RTU)
18E1 MODBUS, RTU)
28O1 MODBUS, RTU)
The parameter decide the communication
protocol. Value 8 represents the transmitted data
is 8 bits; N,E,O indicate odd or even:
N: do not use this bit.
E: it represents 1 is even bit.
O: it represents 1 is odd bit.
Value 1 or 2 indicates communication of 1 bit or
2 bits.
0-3
0
74
Communi
cation
error
handling
When communication happens error, if choose:
0: keep working.
1: alarm and stop working.
0-1
0
75
Zero-speed
detection
point
1.If the motor running speed is less than the
value of this parameter, the ZSP(zero speed) of
digital output(DO) is ON, or else OFF.
If ZCLAMP of digital input(DI) is ON and speed
command is less than the value of this parameter,
the value of speed command is forced to be zero.
0-1000
r/min
10
76
Speed
coincidenc
e range
When the difference between the actual speed
and the instruction speed is less than this setting,
the UCO2N(speed coincidence) is ON, otherwise
OFF.
0-1000
r/min
10
77
2
nd
numerator
of
Refers to parameter FA12.
0-32767
0