Chapter 7 Parameters
1:Soft reset is effective and the system will restart.
Set to:
0: System alarm clear is invalid.
1: System alarm clear is effective.
4: single-turn absolute encoder.
5: multi-turn absolute encoder.
1.Set the load inertia ratio of the motor rotating
inertia.
2.The setting value=((load inertia+rotating
inertia) / rotating inertia)×100.
In torque control mode(FA4=2), when
TRQ1=OFF, TRQ2=OFF, internal torque 1 is as
the torque command.
In torque control mode(FA4=2), when
TRQ1=ON, TRQ2=OFF, internal torque 2 is as
the torque command.
In torque control mode(FA4=2), when
TRQ1=OFF, TRQ2=ON, internal torque 3 is as
the torque command.
In torque control mode(FA4=2), when
TRQ1=ON, TRQ2=ON internal torque 4 is as
the torque command.
MODBUS communication address.
MODBUS
communic
ation baud
rate
MODBUS communication baud rate.