Chapter 7 Parameters
83
27
HOLD
Internal Position
Control
Command Stops
In internal position register mode, the motor will stop
rotating if the signal is active(It can only work when
internal position mode FA-14=3).
28
CTRG
Internal Position
Command
Triggers
In internal position register mode, the signal will be
triggered once the internal position register control
commands(POS0-2) are chosen, and then the motor will
rotate according to the internal position register command.
Only when ZSPD=1(digital output) it would receive a next
internal position command trigger.
29
POS0
Internal Position
Command
Selection0
The corresponding relationship of the internal position
selection:
Position
Command
POS2
POS1
POS0
CTRG
Parameter
F1
0
0
0
F4-2
F4-3
F2
0
0
1
F4-5
F4-6
F3
0
1
0
F4-8
F4-9
F4
0
1
1
F4-11
F4-12
F5
1
0
0
F4-14
F4-15
F6
1
0
1
F4-17
F4-18
F7
1
1
0
F4-20
F4-21
F8
1
1
1
F4-23
F4-24
30
POS1
Internal Position
Command
Selection1
31
POS2
Internal Position
Command
Selection2