2FD/2FF/2FG
2-4-1
Timing chart No. 1 From the main switch turned on to machine stabilization
MSW: On
MSW
FH-M
FH-S
DM
DB REM
YC31-1
YC1-5
YC1-6
YC11-9,11
YC7-1
CFM (second speed)
CFM (first speed)
PM
TC REM
YC8-12
YC7-10
500 ms
500 ms
10 s
*3
100 ms
+400 V +3000 V +400 V
13 s
3 s
900 ms
2 s
1000 ms
*1: Copying is enabled as follows:
1. When fixing temperature at the main switch turning on is 100
°C/212°F or lower
Absolute humidity is 15 g/m
3
or higher:
Copying is enabled 120 s after fixing heater M (FH-M) turning on.
2. When fixing temperature at the main switch turning on is 100
°C/212°F or lower
The fixing temperature at the main switch turning on is 13
°C/55.4°F or higher and the ambient temperature is 18
°C/64.4°F or higher:
Copying is enabled at the earlier timing of either 41 s after fixing heater M (FH-M) turning on or when the copier enters sec
ondary stabilization.
Other than the above:
Copying is enabled at the later timing of either 69 s after fixing heater M (FH-M) turning on or when the copier enters secon
dary stabilization.
3. Other conditions than 1 and 2
Copying is enabled when the copier enters secondary stabilization.
*2: Rotates for 180 s at full speed when the fixing temperature at the main switch turning on is 100
°C/212°F or lower, and the absolute humidity is 15 g/m
3
or higher.
*3: 60 s when the fixing temperature at main switch turning on is 100
°C/212°F or lower, and the absolute humidity is 15 g/m
3
or higher.
Primary stabilization
fixing temperature
110°C/230°F
Secondary stabilization
fixing temperature
165°C/329°F
Copying enabled
*1
Half speed
Half speedFull speed
Full speed
*2
30 s
15 s
700 ms

Table of Contents

Related product manuals