102 Artiglio Master Code User Manual
- Clean and lubricate bead breaker rail (3, Fig.
79b):
Clean with environmentally-friendly solvents
and lubricate with ROLOIL SUPER LUBRICANT
PTFE synthetic gel or equivalent.
To carry out every two months
- Check emergency arrest button function (4,
Fig. 79c):
If operating properly, the stop button will appear
on the display.
Otherwise, contact technical assistance.
To carry out every two months
- Check condition of tool carriage end stops (5,
Fig. 79d - 6, Fig. 79e):
No breakage or permanent deformation must be
present.
If present, contact technical assistance.
To carry out every six months.
- Check condition of the rubber guards on the
bead breakers and tool head (7, Fig. 79f) and
tool head (8, Fig. 79g):
The guards must be present, with no breakage or
permanent deformation evident.
Otherwise, contact technical assistance.
To carry out every three months
- Check condition of the bead breaker tilting
travel limit pad (9, Fig. 79h):
No breakage or permanent deformation must be
7
79f
79d
5
6
79e
4
79c
79b
3