PBD175 (Spire 3.0)) Service Manual
© 2015-2016, Cornelius Inc. - 13 - Publication Number: 620062609SER
6
Empty the plastic pail and prepare approximately five gallons of sanitizing solution. See sanitizing solution
instructions on page 11.
7
Submerge the BIB disconnects in the sanitizing solution.
8
Sanitizing fittings must be attached to each BIB disconnect. If these fittings are not available, the fittings
from empty BIB bags can be cut from the bags and used. These fittings open the disconnect so the sanitiz-
ing solution can be drawn through the disconnect.
9
Place all the BIB disconnects into the pail of sanitizing solution.
10
Select and press the syrup or water icon to be cleaned. Refer to Table 2 on page 14.
NOTE: Water will also be dispensed in this mode when dispensing any brand or flavor.
11
Enter the priming mode to prime up to five valves at a time.
12
Remove the nozzle components, clean in a soap solution, rinse and replace. Refer to Figure 13 and Figure
14.
Table 1.
Step Action