PBD175 (Spire 3.0)) Service Manual
© 2015-2016, Cornelius Inc. - 19 - Publication Number: 620062609SER
Sanitization
This selection graphically prompts the technician through the sanitization cycle. This feature includes timing func-
tions that will not let the user continue until after the sanitization step has been completed. The screens are shown
in Figure 25.
Figure 25.
Priming
This selection opens the selected valve for an unlimited time, allowing the technician to purge the line. This feature
allows the technician to purge the lines during install or when changing out a brand or flavor.
Figure 26.
View Layout
This selection shows the mapped valves as to how they will appear in the user screen. The valve selected is high-
lighted.