8-ORDINARY MAINTENANCE 8-9
COROB™ TATOCOLOR
Each filter is provided with a tap, whose color changes according to the type of filtering net it
contains. When replacing the filtering net, refer to the following table in order to request the right
mesh.
Color of the tap Type of filtering net
inside the filter (mm x mm)
BLACK 0.4 x 0.4
YELLOW 0.8 x 0.9
BLUE 1.1 x 1.1
GREEN 1.7 x 1.8
RED no filtering net
Reset the machine as follows:
8. Open all of the canister taps.
9. Reassemble the protection panels.
10. Connect the machine to the power mains and switch it on (chapter 6.2).
The machine will initialize when it is turned on; during recirculation the dispensing circuits
will fill again with colorant.
11. Check inside the canisters to make sure that the recirculation caused by initialization is
enough to fill the dispensing circuits with colorant. When colorant begins entering the
canisters through the recirculation connectors, the circuits are full. If the recirculation caused
by initialization is not sufficient to send colorant into the canisters, send an additional colorant
recirculation command from the application program. Recirculate the colorant until it flows
continuously into the canisters.
12. Close the canisters with their corresponding lids, and close the covers of the canister
sections.