197
RX Rate (1-
15625)
Use this to limit RX bandwidth for the profile being configured. This rate is implemented using the
following equation: 1 value = 64kbit/sec. (ex. If the user selects an RX rate of 10 then the ingress
rate is 640kbit/sec.) The user many select a value between 1 and 15625 or tick the No Limit check
box. The default setting is No Limit.
Time Range
Name
Tick the check box and enter the name of the Time Range settings that has been previously
configured in the Time Range Settings window. This will set specific times when this access rule
will be implemented on the Switch.
Counter
Use the drop-down menu to specify if the Counter feature should be Enabled or Disabled.
Ports
When a range of ports is to be configured, the Auto Assign check box MUST be ticked in the
Access ID field of this window. If not, the user will be presented with an error message and the
access rule will not be configured. Ticking the All Ports check box will denote all ports on the
Switch.
To view the settings of a p reviously correctly configured rule, click the corresponding Show Details button on the Access Rule
List window to view the following window: