(1) Filter (2) Dust Cap
(3) Evacuator Valve
1. The air cleaner uses a dry ele-
ment. Never apply oil.
2. Make sure that dust is not accu-
mulated over the half of the dust
cap. Remove the dust cap, wipe
out any dust and clean the filter
every week. If the tractor is oper-
ated in extremely dusty conditions,
daily inspection is required.
3. Do not service the filter unless it
should be cleaned.
CLEANING AND REPLACING AIR CLEANER FILTER (T)
tC2O721B
4. For lter replacement, refer to the
instruction for replacing the air
cleaner lter for every year.
To clean the lter, use only clean dry
compressed air on the inside of the
lter. Air pressure at the nozzle must
not exceed 2 kgf/cm² (29 psi). Main-
tain reasonable distance between
the nozzle and the lter.
EVACUATOR VALVE
Open the evacuator valve gab by
ngers once a week under ordinary
conditions or daily when used in
dusty conditions to get rid of large
particles of dust and dirt.
The air cleaner will only fulll
its function if it is correctly
and regularly maintained. A
poorly maintained air cleaner
will mean loss of power, ex-
cessive fuel consumption and
a reduction in engine life.
Do not run the engine with l-
ter element removed.
•
•
IMPORTANT
Be sure to ret the cover with
the arrow (on the rear of
cover) upright. If the cover is
improperly fitted, the evacu-
ator valve will not function
and dust will adhere to the
element. (Refer to the instruc-
tio ns for re plac ing th e air
cleaner lter for every year in
Chapter Maintenance.)
•
IMPORTANT