3.4 Powering on the Keypad
The keypad is registered to the controller within five seconds after it is powered on. Before
registration, the LED indicators in the area 18 glows, and LCD display shows the keypad version
information.
3.5 Factory Default Settings
Zone is set as N.O. type by default.
Zone 8 is set as siren fault by default.
Access Codes
Technician: 1961.
Supervisor: 1234.
Access is required for Arming: Yes.
Network
The default IP address is 192.168.1.108.
Others
2G/4G is disabled by default.
P2P is disabled by default. The DMSS app cannot access the controller.
REMOTE CONF
is
ON
by default. The alarm configuration tool can connect to the controller.
3.6 Lead-acid Battery
When the controller is powered on by the battery instead of the main power, it automatically turns
off when the battery is consumed up to 10.8 VDC. Before the main power restarts supplying power,
the controller will not repeatedly restart because it will cause damage to the battery due to over-
discharging.

Table of Contents

Other manuals for Dahua DHI-ARC3008C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua DHI-ARC3008C and is the answer not in the manual?

Dahua DHI-ARC3008C Specifications

General IconGeneral
BrandDahua
ModelDHI-ARC3008C
CategoryController
LanguageEnglish

Related product manuals