User’s Manual
55
Item Setting
POLAR
The choice of the output polarity determines the at rest status of
the output itself. In practice, the output can be placed in HIHG or
LOW electrical status (high status gets more security)
●
DIRECT
●
REVERSE
If you press to confirm the option, you will exit and the
output will immediately take on the selected polarity.
System Outputs
The system outputs follow on from general system conditions regardless of the areas.
Table 7-10 System outputs programming
Item Setting
TYPE
●
SIREN ALARM
: Follows the generic alarm condition and the timing is in
according to
SYSTEM FUNCTIONS
setting.
●
SYSTEM TAMPER
: Follows the controller tamper condition.
●
SIREN TAMPER
: Follows the siren tamper condition.
●
KEYPAD TAMPER
: Follows the keypad tamper condition.
●
COM1/2 TROUBLE
: Follows a fault condition on the
COM1/2
generated by the bus modules.
●
WALK TEST
: Follows the placing of the controller in
WALK TEST
mode.
●
Technician
: Follows the entry of the
Technician
into programming.
●
CODE ERROR
: This type of output activates when the counter for the
number of false codes entered reaches the parameter set in
SYSTEM
FUNCTIONS
. The duration of the output activations is 3 minutes.
●
COM. BUSY
: This type of output follows telephone communication in
progress.
●
TROUBLES
: Follows a failure of troubles that include a loss of
PSTN
LINE
, a loss of GSM telephone line, antenna tamper, main power supply
loss, battery loss, low battery voltage, SIM expiry, time abnormality.
POLAR
Select the output polarity.
●
DIRECT
●
REVERSE
7.10 Areas
Step 1 After entering the installer menu, press and to scroll up and down until you reach
the
AREAS
menu.