User’s Manual
24
Table 4-3 Key combination operations
Key Function
+ 0 (F0)
●
On the main screen, press + 0 (F0) to view the GSM
connection status, which is shown with eight bars.
●
Press + 0 (F0) again to return to the main screen.
The system automatically returns to the main screen within 2
minutes if no operations are performed.
+ 1 (F1)
●
Panic activation (silent activation or with sirens and keypad
buzzer).
●
On the menu of
ZONE TROUBLES
,
ZONE MANAGER
, and
CHIME ZONES
, press + 1 (F1) to go to the area selection
screen to select, search and filter through areas.
●
On the
OUTPUTS
menu, press + 1 (F1) to do a test to the
output circuit, and active is shown.
+ 2 (F2)
●
Robbery activation (silent activation).
There is no response on the screen but this event is recorded
in the log.
●
On the menu of
ZONE TROUBLES
,
ZONE MANAGER
, and
CHIME ZONES
, you can select, search and filter through
zones.
●
Edit text on the screen such as description of module, zone,
user code, output, timer and display.
●
Edit telephone number, SMS number, and SIM number on the
TEL NUMBER
menu, and PSTN number on
MONITOR
STATION
menu.
+ 3 (F3)
●
Medical activation (with keypad buzzer)
●
On the
WALK TEST
menu, switch between individual test and
multiple test.
●
On the
TEL NUMBER
menu, start a phone call test or
message test.
+ 4 (F4)
●
Fire alarm activation (with keypad buzzer and siren).
●
On the
TEL NUMBER
menu, stop a phone call test.
+ 7 (F7)
●
On the main screen, press + 7 (F7) to view the SIA
connection status.
●
Press + 7 (F7) again to return to the main screen.
The system automatically returns to the main screen within 2
minutes if no operations are performed.
+ (1-8) Search for specified zones under the specified area.
+ (01-99) Search for areas to which the specified zone belongs.