Category Event No. Setting CID Code
Zone Report Code
Group
346-353
Wired Zone 1-8
Alarm
The CID code changes automatically
according to the type of protection zone.
●
Wired Zone Instant Alarm: 130
●
Wired Zone Fire Alarm: 110
●
Wired Zone Medical Alarm: 100
●
Wired Zone Panic Alarm: 120
●
Wired Zone Robbery Alarm: 122
●
Wired Zone Water Leak Alarm: 154
●
Wired Zone 24H Alarm: 133
●
Wired Zone Entry 1 Delay Alarm: 134
●
Wired Zone Entry 2 Delay Alarm: 134
●
Others: 130
354-361
Wired Zone 1-8
Tamper
144
362-369
Wired Zone 1-8
Exclusion
570
370-377
Wired Zone 1-8
Short
142
378-385
Wired Zone 1-8
Mask
391
426-489
Wired Zone 9-72
Alarm
The CID code changes automatically
according to the type of protection zone.
●
Wired Zone Instant Alarm: 130
●
Wired Zone Fire Alarm: 110
●
Wired Zone Medical Alarm: 100
●
Wired Zone Panic Alarm: 120
●
Wired Zone Robbery Alarm: 122
●
Wired Zone Water Leak Alarm: 154
●
Wired Zone 24H Alarm: 133
●
Wired Zone Entry 1 Delay Alarm: 134
●
Wired Zone Entry 2 Delay Alarm: 134
●
Others: 130
490-553
Wired Zone 9-72
Temper
144
554-617
Wired Zone 9-72
Exclusion
570
618-681
Wired Zone 9-72
Short
142
682-745
Wired Zone 9-72
Mask
391
Step 4 Press to return to the
DIGITAL FORMAT
menu.
Then you can press and to move to the next menu or press to exit from the
installer menu.