Symbologies
110
Magellan
TM
800i
Codabar continued
Codabar Stitching
Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to
the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s soft-
ware, and the data will be decoded if all bar code proofing requirements are met.
NOTE
Only functions when
Fixed Length Decoding is enabled.
START / END
PROGRAMMING BAR CODES
Disable Codabar Stitching
DEFAULT
Enable Codabar Stitching
06AD00(CR)
06AD01(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight306.2 g