EasyManuals Logo

Datalogic Magellan 800i User Manual

Datalogic Magellan 800i
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
2D Symbologies
142
Magellan
TM
800i
Maxicode
Disable/Enable Maxicode
When disabled, the scanner will not read Maxicode labels.
START / END
PROGRAMMING BAR CODES
Disable Maxicode
DEFAULT
Enable Maxicode
03D000(CR)
03D001(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight306.2 g

Related product manuals