EasyManuals Logo

Datalogic MAGELLAN 8300 Product Reference Guide

Datalogic MAGELLAN 8300
558 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
Flowcharts
Product Reference Guide 4-13
Figure 4-7. Problem Isolation: Remote Display
Call Tech Support
DONE
DONE
REMOTE DISPLAY
START
YES
YES
YES
YES
NO
NO
NO
NO
Is the
unit configured
for a Remote
Display
?
Is the
problem
fixed
?
Is the
problem
fixed
?
Is the
problem
fixed
?
Replace the
Remote Display
Use the programming bar
codes in Section 6 to
enable operation using a
Remote Display.
Verify that the Remote
Display cable is securely
attached to the external
Remote Display port and
reset the scanner.
Scanner-scale models that include
a Remote Display when shipped
from the factory, are configured
for use with the display. If you're
unsure of the settings for your
unit, contact Tech Support.
Re-connect using a
known-good Remote
Display. Reset the
scanner and retest.

Table of Contents

Other manuals for Datalogic MAGELLAN 8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8300 and is the answer not in the manual?

Datalogic MAGELLAN 8300 Specifications

General IconGeneral
Read rate (max)3900 reads/s
Decoding standards1D, GS1 DataBar
Standard interfacesKeyboard Wedge, RS-232
USB 2.0 ports quantity1
Input voltage100 - 250 V
Product colorMetallic
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width292 mm
Height130 mm

Related product manuals