6. Attach the ribbon to the Take-Up Hub. Enter the Quick Test Mode and select 100 Quick Ribbon
Test Labels then press TEST to begin printing.
Take-Up Hub
Printhead
Assembly
7. Observe the ribbon for rippling and bagging as it travels from the Printhead Assembly to the Take-
Up Hub. If smooth and if printed labels show no evidence of ribbon wrinkling, proceed to Step 8;
otherwise, slightly loosen the Ribbon Shield Adjustment Screws. Move the Ribbon Shield forward
or backward to smooth the ribbon. Tighten the Ribbon Shield Adjustment Screws and print several
more labels to verify adjustment; repeat if necessary.
Printhead Assembly
Ribbon Shield
Ribbon Shield
Screws
8. Press TEST to stop printing.
9. Install operating media and ribbon. Adjust the Printhead Leveling Cam, if needed. Send a label
format from the host. Examine the printed labels and then, if needed, slightly readjust the Ribbon
Shield.

Other manuals for Datamax I-Class

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax I-Class and is the answer not in the manual?

Datamax I-Class Specifications

General IconGeneral
Print MethodThermal Transfer/Direct Thermal
Resolution203 dpi, 300 dpi, or 600 dpi
Max Print Speed10 inches per second (254 mm/s)
InterfaceUSB, Serial, Parallel
Media TypesPaper, Polyester, Polypropylene, Vinyl, Nylon

Related product manuals