Removal and Replacement
4-31
If installing P/N 51-2348-00, configure
the settings of the Jumpers according to
the equipped options and default
requirements:
Scanner equipped: E1 & E2, E5 &
E6;
RFID equipped: E2 & E3, E4 & E4;
COM2 DTR Active (default): E7 & E8;
and,
Ribbon Motion (default): E11 & E12.
2. Place the Backplane PCB into the Card Cage and then secure it with the four Screws.