Removal and Replacement
4-16
Media Sensor &
Cable Assembly
Screw
Outer Bearing
Plate
Installation:
1. Route the Cable Assembly through the Centerplate opening and then slide in Media
Sensor.
Media
Sensor
Centerplate
2. Replace the Outer Bearing Plate and start, but do NOT tighten, the Screw.
3. Ensure that the Leveling Cam is loose and then latch the Printhead Assembly.
4. While pushing downward on the Printhead Assembly (see arrow, below), pull down on
the Outer Bearing Plate and tighten the Screw.