Removal and Replacement
4-23
4.9 Thermal Transfer Assembly
Removal:
1. Turn OFF and unplug the printer.
2. Remove the three Screws that secure the Thermal Transfer Assembly and then remove
the Thermal Transfer Assembly from the Centerplate.
Screws
Thermal Transfer Assembly
Centerplate
Installation:
Position the Thermal Transfer Assembly over the opening in the Centerplate and secure it
using the three Screws.
4.9.1 Take-up Hub & Clutch Assembly
Removal:
1. Remove the Thermal Transfer Assembly; see Section 4.9.
2. Remove the C-Clip and Outer Bearing from the Take-Up Hub Shaft.
3. Slide the Take-up Hub and Inner Bearing out of the Assembly Casting then remove the
Clutch Assembly.

Table of Contents

Other manuals for Datamax M-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax M-Class Mark II and is the answer not in the manual?

Datamax M-Class Mark II Specifications

General IconGeneral
Media SensorAdjustable reflective and transmissive sensors
Print MethodThermal Transfer
Print Resolution203 dpi
Memory8 MB Flash, 16 MB SDRAM
Interface OptionsUSB, Serial, Ethernet, Parallel
Media TypeRoll-fed, die-cut, continuous, fan-fold, tags, ticket stock
Media Width1.0 in (25.4 mm) to 4.65 in (118 mm)
Media Thickness0.0025 in (0.0635 mm) to 0.010 in (0.254 mm)
Media Roll Diameter8 inches (203 mm) max
Ribbon Width1 to 4.33 inches (25.4 to 110 mm)
Ribbon Length1968 ft (600 m)
Ribbon Core1 inch (25.4 mm)
Label Width Range1.0 in (25.4 mm) to 4.65 in (118 mm)
Label Length Range0.25 to 39 inches (6.35 to 991 mm)