Figure 63. Front fan 2
Steps
1. Align the tabs on the fan with the slots on the chassis.
2. Insert the chassis fan at an angle into the slot in the chassis.
3. Press the chassis fan into the slot until the release tab locks into place.
4. Connect the fan cable to the connector on the system board.
NOTE: Follow the procedure from step 1 to 4 for fan 2.
5. Replace the M3x5 screw to secure the fan 1 to the chassis.
Next steps
1. Install the air shroud.
NOTE: For systems with 500W/1000W PSU only.
2. Install the side cover.
3. Follow the procedure in after working inside your computer.
Removing the rear fan for 300W PSU systems
CAUTION: The information in this removal section is intended for authorized service technicians only.
Removing and installing Field Replaceable Units (FRUs) 91