4
VFD-L Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-1
CHAPTER 4 DIGITAL KEYPAD OPERATION
4.1 Description of Digital Keypad
This digital keypad includes two parts: Display panel and keypad. Display panel
provides the parameter display and shows operation status of the AC drive. Keypad
provides programming interface between users and AC drives.
UP/DOWN
Function
Display key
Data
Confirmation key
RUN/STOP
Frequency
setting knob
LED display
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3
RS-485
M
ode/Reset
B
y pressing the
³
mode
´
key repetitively, the display will show status at the AC driv
e
s
uch as the reference frequency, output frequency, and output current. If the driv
e
s
tops due to a fault, correct the fault first, then press this key to reset the drive.
P
ROG/DATA
P
ressing the
³
PROG/DATA
´
key will store entered data or can show factory store
d
d
ata.
R
un/Stop
P
ress to Start or Stop the AC drive operation. This key can only be used to Sto
p
t
he AC Drive when the drive is controlled by the External Control Terminals.

Table of Contents

Other manuals for Delta VFD-L Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-L Series and is the answer not in the manual?

Delta VFD-L Series Specifications

General IconGeneral
Control MethodV/F Control
Output Voltage0 to Input Voltage
Cooling MethodFan Cooling
Enclosure RatingIP20
Overload Capacity150% for 60 seconds
ProtectionOver-voltage, Over-current, Overheat, Under-voltage, Short circuit
Braking UnitBuilt-in
Operating Temperature-10°C to 50°C (14°F to 122°F)
Digital Inputs5 programmable digital inputs
Analog Input0-10V, 4-20mA
Communication InterfaceRS-485 (Modbus)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Humidity90% RH, non-condensing
AltitudeUp to 1000m without derating
Input Voltage200-240V, 380-480V