VFD-L Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-38
Output
Frequency
Output
Voltage
08-06
08-05
08-04=d1
Power
Input
Maximum Allowable
Power Loss Time
Baseblock Time
Speed Search
Speed
Synchronization
Detection
Speed search starts
with the Master
Frequency
8 - 08
S
kip Frequency 1 Upper Bound
F
actory Setting: d 0.0
8 - 09
S
kip Frequency 1 Lower Bound
F
actory Setting: d 0.0
8 - 10
S
kip Frequency 2 Upper Bound
F
actory Setting: d 0.0
8 - 11
S
kip Frequency 2 Lower Bound
F
actory Setting: d 0.0
8 - 12
S
kip Frequency 3 Upper Bound
F
actory Setting: d 0.0
8 - 13
S
kip Frequency 3 Lower Bound
F
actory Setting: d 0.0
Settings d 0.0
d 400Hz Unit: 0.1Hz
08-06
08-05
08-04=d2
Maximum
Allowable Power Loss Time
Baseblock Time
Speed search starts with
Min. Output Frequency
These parameters determine Skip frequency. It will cause the AC drive to skip
operation at these frequency ranges with continuous frequency output.
Pr.8-9, Pr.8-11,Pr.8-13 are for Lower Bound setting, and the settings should follow as
Pr.8-9
x
Pr.8-11
x
Pr.8-13.
8 - 14
A
uto Restart After Fault
F
actory Setting: d 0
Settings d 0 to d 10
After fault occurs (allowable faults: over-current OC, over-voltage OV), the AC drive can
be reset/restarted automatically up to 10 times. Setting this parameter to 0 will disable
the reset/restart operation after any fault has occurred. When enabled, the AC drive will
restart with speed search, which starts at the Master Frequency.

Table of Contents

Other manuals for Delta VFD-L Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-L Series and is the answer not in the manual?

Delta VFD-L Series Specifications

General IconGeneral
Control MethodV/F Control
Output Voltage0 to Input Voltage
Cooling MethodFan Cooling
Enclosure RatingIP20
Overload Capacity150% for 60 seconds
ProtectionOver-voltage, Over-current, Overheat, Under-voltage, Short circuit
Braking UnitBuilt-in
Operating Temperature-10°C to 50°C (14°F to 122°F)
Digital Inputs5 programmable digital inputs
Analog Input0-10V, 4-20mA
Communication InterfaceRS-485 (Modbus)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Humidity90% RH, non-condensing
AltitudeUp to 1000m without derating
Input Voltage200-240V, 380-480V

Related product manuals