VFD-L Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
SPECIFICATIONS
oltage Class 115V 230V
odel Number VFD-
L
A/B 002 004 002 004 007 015
pplicable Motor Output (kW) 0.2 0.4 0.2 0.4 0.7 1.5
Rated Output Capacity (KVA)
ated Output Current (A) 1.6 2.5 1.6 2.5 4.2 7.0
ax. Output Voltage (V)
3-phase correspond
o double input voltag
Three-phase corresponds to input voltage
Output Rating
ated Frequency (Hz) 1.0~400Hz
ated Input Current (A) 6 9 4.9/1.9
6.5/2.7 9.7/5.1 */9
nput voltage Tolerance
Single phase
90~132V 50/60Hz
Single / 3-phase
180~264V 50/60Hz
3-phase
180~264V
50/60Hz
Power
requency tolerance
±
5%
ontrol system
SVPWM (Sinusoidal Pulse Width Modulation, carried frequency
3kHz~10kHz)
utput Frequency Resolution
0.1Hz
orque Characteristics
Including the auto-torque, auto-slip compensation, starting torque can be
150% at 5 Hz
verload Endurance 150% of rated current for 1 minute
ccel/Decel Time 0.1~600Sec. (can be set individually)
/F pattern V/F pattern adjustable
Control Characteristics
tall Prevention Level 20~200%, setting of Rated Current
eypad
Setting by
çð
keys or V.R
Frequenc
Setting
xternal Signal
otentiometer-5K
Ω
/0.5W, DC 0 ~ +10V (input impedance 100K
Ω
), 4~20m
output impedance 250
Ω
), multi-function inputs1 to 3 (3steps, JOG,
P/DOWN command), communication setting
Operation
Setting
eypad Setting by RUN//STOP keys
Signal
xternal Signal
M0,M1,M2,M3 can be combined to offer various modes of operation,
RS-485 communication port
Multi-function Input Signal
Multi-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/dece
switch, counter, PLC Operation, external Base Block (NC,NO) selection
Operating Characteristics
Multi-function Output Signa
AC Drive Operating, Frequency Attained, Non-zero speed, Base Block,
Fault Indication, Local/Remote indication, PLC Operation indication.
Other Function
AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records
Adjustable Carried Frequency, Starting Frequency Setting of DC Braking
Over-Current Stall Prevention, Momentary Power Loss restart, Reverse
Inhibition, Frequency Limits, Parameter Lock/Reset
Protection
Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal
Overheating, Self-testing
Other Including EMI Filter
Cooling Forced air-cooling
Installation Location Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust
Ambient Temperature
-10
:
-40
:
(Non-Condensing and not frozen)
Storage Temperature
-20
:
to 60
:
Ambient Humidity Below 90%RH (non-condensing)
Environment
Vibration 9.80665m/s
2
(1G) less than 20Hz, 5.88m/s
2
(0.6Gat) 20 to 50Hz