Serial port Configure Remote Access mode
Digi Connect EZ Mini User Guide
112
where value is one of:
n none
n rts/cts
n xon/xoff
13. Configure the session settings.
a. Set the characters used to start an escape sequence:
(config)>serial port1 escape string
(config)
If no characters are defined, the escape sequence is disabled. The default is ~b.
b. Limit access to the serial port to a single active session:
(config)>serial port1 exclusive true
(config)
c. Set the number of bytes of output from the serial port that are written to buffer. These
bytes are redisplayed when a user connects to the serial port.
(config)>serial port1 history bytes
(config)
The default is 4000 bytes.
d. Set the amount of time to wait before disconnecting due to user inactivity:
(config)>serial port1 idle_timeout value
(config)
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set idle_timeout to ten minutes, enter either 10m or 600s:
(config)>serial port1 idle_timeout 600s
(config)
The default is 15m.
14. Configure monitor settings.
a. (Optional) Enable monitoring of CTS (Clear to Send) changes on this port:
(config)>serial port1 monitor cts true
(config)
b. (Optional) Enable monitoring of DCD (Data Carrier Detect) changes on this port:
(config)>serial port1 monitor dcd true
(config)
15. (Optional) Configure autoconnect: