EasyManua.ls Logo

Digi Connect EZ Mini - Page 112

Digi Connect EZ Mini
774 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial port Configure Remote Access mode
Digi Connect EZ Mini User Guide
112
where value is one of:
n none
n rts/cts
n xon/xoff
13. Configure the session settings.
a. Set the characters used to start an escape sequence:
(config)>serial port1 escape string
(config)
If no characters are defined, the escape sequence is disabled. The default is ~b.
b. Limit access to the serial port to a single active session:
(config)>serial port1 exclusive true
(config)
c. Set the number of bytes of output from the serial port that are written to buffer. These
bytes are redisplayed when a user connects to the serial port.
(config)>serial port1 history bytes
(config)
The default is 4000 bytes.
d. Set the amount of time to wait before disconnecting due to user inactivity:
(config)>serial port1 idle_timeout value
(config)
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set idle_timeout to ten minutes, enter either 10m or 600s:
(config)>serial port1 idle_timeout 600s
(config)
The default is 15m.
14. Configure monitor settings.
a. (Optional) Enable monitoring of CTS (Clear to Send) changes on this port:
(config)>serial port1 monitor cts true
(config)
b. (Optional) Enable monitoring of DCD (Data Carrier Detect) changes on this port:
(config)>serial port1 monitor dcd true
(config)
15. (Optional) Configure autoconnect:

Table of Contents

Related product manuals